Tektronix DPO4000 Instrukcja Użytkownika Strona 298

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 585
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 297
Commands Listed in Alphabetical Order
Examples
POWER:SOA:LIN
EAR:XMAX 700
sets the XMAX value to 700.0000.
POWER:SOA:LINEAR:XMAX ? might return :POWER:S OA:LINear:XMAX
500.0000
indi
cating that the XMAX value for linear plot type is set to 500.0000.
POWer:SOA:LINear:XMIN
Sets or returns the user XMIN value for use in linear SOA calculations.
Conditions
This command requires a DPO4PWR application module.
Group
Power
Syntax
POWer:SOA:LINear:XMIN <NR3>
POWer:SOA:LINear:XMIN?
Arguments
<NR3> is the XMIN value used for linear SOA calculations.
Examples
POWER:SOA:LINEAR:XMIN 2 sets the XMIN value to 2.0000.
POWER:SOA:LINEAR:XMIN ? might return :POWER:S OA:LINear:XMIN
0.0E+0
indicating that the XMIN value for linear plot type is set to 0.0E+0.
POWer:SOA:LINear:YMAX
Sets or returns the user YMAX value for use in linear SOA calculations.
Conditions
This command requires a DPO4PWR application module.
Group
Power
Syntax
POWer:SOA:LINear:YMAX <NR3>
POWer:SOA:LINear:YMAX?
Arguments
<NR3> is the YMAX value used for linear SOA calculations.
2-288 MSO4000 and DPO4000 Series Programmer Manual
Przeglądanie stron 297
1 2 ... 293 294 295 296 297 298 299 300 301 302 303 ... 584 585

Komentarze do niniejszej Instrukcji

Brak uwag