Pull-down Menus
MTG100 & MTG300 MPEG Generator User Manual
3Ć15
Figure 3Ć6: TOT Item dialog box
Table 3Ć14: TOT Item dialog box parameters
Parameter Description
PID Shows the PID value of the TOT you are inserting.
Table ID Shows the table_id value of the TOT you are inserting.
Interval Sets the period between occurrences of the TOT in the transport stream.
You can set the value from 0.5 s to 120 s in 0.1 s steps.
Init Date & Time Sets the initial date and time (year / month / day hour : minute : second) of
the TOT.
Table 3Ć15: Bezel menu commands for the TOT Item dialog box
Command Description
Undo Stress Cancels any setting changes and closes the dialog box.
Keep Stress Enables all setting changes. When you apply setting changes, data output
from the MPEG generator is stopped. You must restart the MPEG generator
output for the setting changes to appear.
When you select the Insert STT... command from the CONFIG pull-down menu
or you select STT... from the Bezel menu of a selected STT icon in the hierarchy
display, the STT Item dialog box appears as shown in Figure 3-7. Use the arrow
buttons to highlight the desired parameter, and then use the rotary knob or
hexadecimal keypad to set values. Press the OK bezel button to apply changes.
. The STT Item dialog box is available from the CONFIG pull-down menu
only when the selected transport stream file is in ATSC format and an STT
(System Time Table) does not already exist in the stream.
STT Item Dialog Box
(MTG300 Only)