
Pull-down Menus
MTG100 & MTG300 MPEG Generator User Manual
3Ć11
Table 3Ć8: Start/End Packet dialog box parameters (Cont.)
Parameter Description
Start Packet Sets the number of the start packet in the transport stream.
End Packet Sets the number of the end packet in the transport stream. The number of
(End Packet-Start Packet) is need to be more than 5000 packets.
Table 3Ć9: Bezel menu commands for the Start/End Packet dialog box
Command Description
Default Resets all of the dialog box settings back to the factory default settings.
Cancel Cancels any setting changes and closes the dialog box.
Apply Applies the settings to the transport stream output.
When you select the PCR Initial Value... command from the CONFIG pull-down
menu, the PCR Start Value dialog box appears as shown in Figure 3-4. Use the
arrow buttons to highlight the desired parameter, and then use the rotary knob or
hexadecimal keypad to set values. Press the OK bezel button to apply changes.
Table 3-10 describes the PCR Start Value dialog box parameters and Table 3-11
describes the Bezel menu commands associated with the dialog box.
Figure 3Ć4: PCR Start Value dialog box
Table 3Ć10: PCR Start Value dialog box parameters
Parameter Description
Base Value Sets the initial value for the program_clock_reference_base value. You can
set the value from 0 to 8589934591. The bracketed number represents the
number of bits for the program_clock_reference_base field.
Extension Value Sets the initial value for the program_clock_reference_extension value. You
can set the value from 0 to 299. The bracketed number represents the
number of bits for the program_clock_reference_extension field.
PCR Start Value Dialog
Box
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Komentarze do niniejszej Instrukcji