Operating Instructions
1502C MTDR User Manual
125
O
F
F
O
F
F
O
F
F
O
N
ac
0.000 ft
D
Figure 124: Cursor Moved to End of Three-Foot Lead-in Cable
NOTE. Vp changes will affect where the reference is set on the cable. Be sure to
set the Vp first, then set the delta to the desired location.
5. To exit HORZ SET REF, use the following procedure:
a. Turn the NOISE FILTER control to HORZ SET REF.
b. Turn DIST/DIV to .1 ft/div. If the distance reading is extremely high,
you might want to use a higher setting initially, then turn to .1 ft/div for
the next adjustment.
c. Turn the
n
o
POSITION control until the distance window reads 0.00 ft.
O
F
F
O
F
F
O
F
F
O
N
ac 0.000 ft
move cursor to reference and Press STORE
Figure 125: Cursor Moved to 0.00 ft
d. Push STORE.
e. Turn NOISE FILTER to desired setting.